Ethernet hybrid card for loads up to 3A
388,19 € Prices plus statutory VAT | plus shipping and handling
Delivery in 2-3 working days
Technical description – Yamutec® 3A 8-fold Ethernet hybrid card
If you want to switch loads of up to 90 watts with your control and regulation circuit, then our 3A 8-fold Ethernet hybrid card is exactly the right thing for your project. The module's 8 optocoupler inputs can record signal voltages from 3V to 30V, with a maximum input current of 10mA. You benefit from the excellent signal processing of the optocouplers, which reliably detect input signals even at very high frequencies.
There are 8 PCN series relays at the outputs of the hybrid module, which ensure reliable galvanic isolation of the load and control circuits. The hybrid card is powered using a pluggable screw terminal and 7V to 24V DC must be applied. We chose a 100/10 Mbit Ethernet connection as the interface for the module. This allows for fast data transfer rates and easy connection to the company network and the Internet.
Area of application of the hybrid module from Yamutec
Our hybrid cards are used wherever you want to switch loads without interference and need to protect your devices from overvoltages or transients. The optocouplers realize reliable and very fast acquisition of input signals. You can switch loads safely and cost-effectively using the 8 relays at the output. You also benefit from the timeout protection on the outputs, which switches the relays on or off immediately in the event of a fault.
Our modules comply with RoHS and EMC. They are therefore perfectly prepared for industrial use. In the robust aluminum housing, the electronics are very well protected from the harsh environment of a production hall and can also be easily mounted on a DIN rail.
The module can be easily connected to the Internet via the 100/10 Mbit Ethnernet interface. This allows for easy remote maintenance and monitoring, which is particularly important for external services or quick action in an emergency. You can view and change the states of the outputs using our Yamutec I/O Remote App.
Signal acquisition and amplification for industrial processes and in research laboratories with our 3A 8-fold Ethernet hybrid card – request an offer now! We also have ETH 16 hybrid modules for load circuits up to 3A Releases!
Technical data
ETHERNET INTERFACE | |
---|---|
supply voltage | External 7V to 24V DC via plug-in screw terminal |
interface | 100/10 Mbit Ethernet (galvanically isolated) IP address can be assigned statically or obtained via DHCP |
control LEDs | Internal 5V supply voltage (green LED) Interface activity (green LED) Timout shutdown (orange LED) I/O activity (blue LED) Error message (red LED) |
EXITS | |
Terminals 1 – 8 | 8 relay outputs, Galvanically isolated via relays Max. switching voltage: 30V AC / 30V DC Max. switching current: 3A AC / 3A DC Max. transport current: 3A AC / 3A DC Max. switching power: 90W Switching time: < 1 ms |
Timeout function | Selectable timeout protection when the module is not reachable. e.g. in the event of a software crash (outputs can be individually selected) |
connector | 2 ROW MULTI CONNECTION SYSTEM 100% protection against mismating Can be coded by cutting off the coding lugs |
ENTRANCES | |
Terminals 9 – 16 | 8 optocoupler inputs 3V – 30V AC/DC signal voltage Isolation voltage: 2.5KV AC for 1 minute Maximum input current: 10mA |
connector | 2 ROW MULTI CONNECTION SYSTEM 100% protection against mismating Can be coded by cutting off the coding lugs |
DIMENSION | |
Dimensions Weight |
135mm x 105mm x 74.5mm (L x W x H) 490g |
Downloads
MANUAL | |
---|---|
Instructions | German English |
SOFTWARE | |
---|---|
sample software | VB6, VB.NET , C#, LabView / without installation |
API | developer tool (Dynamic link library) |
DATA SHEET | |
---|---|
Outputs 1 – 16 | Slimline Low Power PCB Relay PCN |